ReeR – ULISSE UPC safety Photocell
Type 2 safety through-beam photocell designed for industrial environments, offering up to 6 meters of detection range with an 8ms response time. It features a PNP safety output (100mA) and operates at 24V DC, protected against reverse polarity. Housed in a robust metal casing, it is resistant to dust, vibration, and suitable for harsh conditions. With an IP65 rating, it operates between 0°C and 55°C and must be properly aligned for effective use.
Request a quote
Model Number | Safety Level | Detection Range | Response time | Power Supply | Safety Output | Protection Rating | Operating Temperature | Weight | Connector Type |
1200300 | Type 2 – SILCL 1 – PL c | 0.8 to 6 meters | < 8 milliseconds | 24V DC ± 20% | PNP, max 100 mA | IP65 | 0°C to 55°C | 192.4 g | M8 (3-pin male) |
Technical Drawings
Attribute | Value |
---|---|
Safety level: | Type 2 – SILCL 1 – PL c (with certified safety interface) |
Detection range: | 0.8 to 6 meters |
Response time: | < 8 milliseconds |
Power supply: | 24V DC ± 20% |
Safety output: | PNP, max 100 mA, light-on |
Emission wavelength: | 880 nm (infrared, modulated) |
Protection degree: | IP65 |
Operating temperature: | 0°C to 55°C |
Body construction: | Metal, dust and vibration-resistant |
MTTFD: | 100 years (per ISO 13849) |
PFHD: | 8.04E-09 (per IEC 61508) |
Weight: | 192.4 g |
Connector type: | M8 (3-pin male) |
Machine Directive 2006/42/EC
IEC 61496-1 & 2: Safety of machinery—Electro-sensitive protective equipment.
IEC 61508: Functional safety of electrical/electronic/programmable electronic safety-related systems.
ISO 13849-1: Safety of machinery—Safety-related parts of control systems.
2014/30/EU: Electromagnetic Compatibility Directive (EMC).
2014/35/EU: Low Voltage Directive (LVD).
UKCA: Complies with UK regulations for machinery safety, electrical safety, electromagnetic compatibility, and hazardous substances (S.I. 2008 No. 1597, S.I. 2016 No. 1101, S.I. 2016 No. 1091, S.I. 2012 No. 3032)