ReeR SAFEGATE SM | Safety Light Curtain with Muting

SM models

With integrated Muting functions.

Two safety PNP static outputs, auto-controlled.

Hardware configurable models allow configuration of the Muting logic and functional parameters via the M12 12-pole main connector wiring.

Built-in, selectable manual/automatic Start/Restart.

M12 5-pole Muting sensor(s) connector for 2 or 4 external Muting sensors with one-way or two-way Muting logic.

Unshielded cables up to 100 meter long.

Protected height: 310 mm … 2260 mm.

SM TRX models

Access control models 2, 3 or 4 beams.

With same characteristics of the SM models but with passive retro-reflector element.

Request a quote

    Model Operating Range Resolution Supply Voltage Safety Outputs Muting Logic  Muting Sensors Electrical Connection Safety Rating
    SM 0-4m or 0-12m 30mm, 40mm, 2, 3 or 4 beams 24 VDC ± 20% 2 PNP- 400 mA at 24 VDC One-way with 2 sensors, two-way with 4 sensors MA muting arms kits, MZ muting brackets kits, External with relay or PNP output M12 5-pole for emitter
    M12 12-pole for receiver
    Type 4
    SIL 3 – SILCL 3
    PL e – Cat. 4
    SM TRX Up to 8m 2, 3 or 4 beams 24 VDC ± 20% 2 fail-safe PNP (400 mA at 24 VDC), self-controlled with protection against short circuit, overload and reverse polarity Two-way with 2 or 4 sensors, one-way with 2 sensors Muting arms TRX kit, Muting brackets with MTRX sensors kit M12 12-pole for emitter
    M12 12-pole for SM TRX receiver
    Type 4
    SIL 3 – SILCL 3
    PL e – Cat. 4

    Accessories

    • columns and floor support columns
    • deflection mirrors for the realization of perimeter protection
    • laser alignment device
    • anti-vibration dampers
    • adjustable brackets

    Part Numbers – SM Resolution 30 mm

    Model Number Protected Height (mm) Overall Height (mm) Number of Beams 
    SM 303 310 395 16
    SM 453 460 545 23
    SM 603 610 695 31
    SM 753 760 845 38
    SM 903 910 995 46
    SM 1053 1060 1145 53
    SM 1203 1210 1295 61
    SM 1353 1360 1445 68
    SM 1503 1510 1595 76
    SM 1653 1660 1745 83
    SM 1803 1810 1895 91
    SM 1953 1960 2045 98
    SM 2103 2110 2195 106
    SM 2253 2260 2345 113
    Attribute Value
    Degree of protection: IP65 and IP67
    Protected height: 310mm – 2260mm
    Signaling: LED status display
    Muting sensors: External with relays or PNP output (dark-on logic), Muting arms kits MA and MA TRX, Muting brackets kits MZ and MZ TRX
    Safety level: SIL 3 Cat. 4 PL e

    2006/42/EC “Machinery Directive”
    2014/30/EU “Electromagnetic Compatibility Directive”

    Safegate Catalogue Installation Guide Mechanical Data