DOLD – LH 5946 | Standstill Monitor Relay – 0061230

The DOLD LH 5946 standstill speed monitor works without the need for encoder sensors or proximity switches. The LH 5946 is most suitable for detection of standstill of 3/1-phase electric motors unilaterally. It functions by measuring the induced EMF of the costing motor. If the induced EMF is near ‘0’, this triggers standstill state – activating the output relay.

Request a quote

    ITEM NUMBER PRODUCT PART NUMBER SUPPLY VOLTAGE (DC) CONTACTS
    0061230 LH5946.48PC/61 24  V 3 NO contacts, 1 NC contact

    Connection Example

     

    Attribute Value
    Width: 45 mm
    Classification: Sensor less
    Cat. / PL: 4/e
    SIL CL: 3
    Max supply voltage: 24 V AC, DC
    Channel: 2
    Connection: Screw terminals, Pluggable screw terminals, Pluggable cage clamp terminals
    Indicator contacts: 2 Semiconductor monitoring outputs, 1 NO contact
    Measuring motor voltage max: 690 V
    Forcibly guided output contacts max: 1 NC contact, 3 NO contacts
    Housing protection std: IP 40 IEC/EN 60529
    Terminals protection std: IP 20 IEC/EN 60529

    EN ISO 13849-1

    IEC/EN 62061

    IEC/EN 61508

    IEC/EN 61511

    EN 61800-5-2

    IEC/EN 60947-5-1

    IEC/EN 61326-3-1

    EN61000-6-7

    EN 55011

    IEC/EN 60529

    IEC/EN 60068-2-6

    IEC/EN 60068-1

    EN 50005

    DIN 46228-1/-2/-3/-4

    IEC/EN 60715

    technical data sheet Flyer standstill LH 5946