Description
Ilion is a Type 2 safety photocell with M18 cylindrical metal body
The Ilion photocells must be connected to control unit for example: standard AU SX or AU SXM control unit with Muting or Mosaic to form a protection system that can be composed of 1, 2, 3 or 4 single beam photocells.
In case of connection with Mosaic safety controller, the number of photocells depends to the configuration of the protection system. (For details on the interface see AU SX, AU SXM and Mosaic control units).
Specifications
Safety level: Type 2, SILCL 1 PL c Cat. 2 (with control unit AUS X or AUS XM or Mosaic)
Protection level: IP65
Number of photocells per control unit: 1 – 4 with AU SX and AU SXM control units
In case of the Mosaic safety controller the number of photocells depends to the number available input related to the system configuration
Compliance
2006/42/EC: Machine Directive
2014/30/EU: Electromagnetic Compatibility Directive
2014/35/EU: Low Voltage Directive
IEC 61496-1 (ed.3) (Type 2) Safety of machinery – Electro sensitive protective equipment – General requirements and tests
IEC 61496-2 (ed.3) (Type 2) Safety of machinery – Electro-sensitive protective equipment – Particular requirements for equipment using active opto-electronic protective devices (AOPDs)
ISO 13849-1:2006 (cat. 2, PL c) Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design
IEC 62061 (ed.1) (SILCL1) Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems
EN 50178:1997 Electronic equipment for use in power installations
EN 55022:2110 Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement
Model | Minimum Detectable Object (mm) | Max Range (m) | Output | Power Supply | Electrical Connections |
---|---|---|---|---|---|
IL 10 | 12 | 8 | PNP – mA | 24 VDC | M12 4-pole |
IL 20 | 12 | 20 | PNP – mA | 24 VDC | M12 4-pole |