Description
SM models
With integrated Muting functions.
Two safety PNP static outputs, auto-controlled.
Hardware configurable models allow configuration of the Muting logic and functional parameters via the M12 12-pole main connector wiring.
Built-in, selectable manual/automatic Start/Restart.
M12 5-pole Muting sensor(s) connector for 2 or 4 external Muting sensors with one-way or two-way Muting logic.
Unshielded cables up to 100 meter long.
Protected height: 310 mm … 2260 mm.
SM TRX models
Access control models 2, 3 or 4 beams.
With same characteristics of the SM models but with passive retro-reflector element.
Specifications
Degree of protection: IP65 and IP67
Protected height: 310mm – 2260mm
Signaling: LED status display
Muting sensors: External with relays or PNP output (dark-on logic), Muting arms kits MA and MA TRX, Muting brackets kits MZ and MZ TRX
Safety level: SIL 3 Cat. 4 PL e
Compliance
2006/42/EC “Machinery Directive”
2014/30/EU “Electromagnetic Compatibility Directive”
Model | Operating Range | Resolution | Supply Voltage | Safety Outputs | Muting Logic | Muting Sensors | Electrical Connection | Safety Rating |
SM | 0-4m or 0-12m | 30mm, 40mm, 2, 3 or 4 beams | 24 VDC ± 20% | 2 PNP- 400 mA at 24 VDC | One-way with 2 sensors, two-way with 4 sensors | MA muting arms kits, MZ muting brackets kits, External with relay or PNP output | M12 5-pole for emitter M12 12-pole for receiver |
Type 4 SIL 3 – SILCL 3 PL e – Cat. 4 |
SM TRX | Up to 8m | 2, 3 or 4 beams | 24 VDC ± 20% | 2 fail-safe PNP (400 mA at 24 VDC), self-controlled with protection against short circuit, overload and reverse polarity | Two-way with 2 or 4 sensors, one-way with 2 sensors | Muting arms TRX kit, Muting brackets with MTRX sensors kit | M12 12-pole for emitter M12 12-pole for SM TRX receiver |
Type 4 SIL 3 – SILCL 3 PL e – Cat. 4 |
Accessories
- columns and floor support columns
- deflection mirrors for the realization of perimeter protection
- laser alignment device
- anti-vibration dampers
- adjustable brackets
Part Numbers – SM Resolution 30 mm
Model Number | Protected Height (mm) | Overall Height (mm) | Number of Beams |
SM 303 | 310 | 395 | 16 |
SM 453 | 460 | 545 | 23 |
SM 603 | 610 | 695 | 31 |
SM 753 | 760 | 845 | 38 |
SM 903 | 910 | 995 | 46 |
SM 1053 | 1060 | 1145 | 53 |
SM 1203 | 1210 | 1295 | 61 |
SM 1353 | 1360 | 1445 | 68 |
SM 1503 | 1510 | 1595 | 76 |
SM 1653 | 1660 | 1745 | 83 |
SM 1803 | 1810 | 1895 | 91 |
SM 1953 | 1960 | 2045 | 98 |
SM 2103 | 2110 | 2195 | 106 |
SM 2253 | 2260 | 2345 | 113 |
Part Numbers – SM Resolution 40 mm
Model Number | Protected Height (mm) | Overall Height (mm) | Number of Beams |
SM 304 | 310 | 395 | 11 |
SM 454 | 460 | 545 | 16 |
SM 604 | 610 | 695 | 21 |
SM 754 | 760 | 845 | 26 |
SM 904 | 910 | 995 | 31 |
SM 1054 | 1060 | 1145 | 36 |
SM 1204 | 1210 | 1295 | 41 |
SM 1354 | 1360 | 1445 | 46 |
SM 1504 | 1510 | 1595 | 51 |
SM 1654 | 1660 | 1745 | 56 |
SM 1804 | 1810 | 1895 | 61 |
SM 1954 | 1960 | 2045 | 66 |
SM 2104 | 2110 | 2195 | 71 |
SM 2254 | 2260 | 2345 | 76 |
Part Numbers – SM Access Control (2, 3 or 4 beams)
Model Number | Protected Height (mm) | Overall Height (mm) | Number of Beams |
SM 2B | 510 | 500 | 2 |
SM 3B | 810 | 400 | 3 |
SM 4B | 910 | 300 | 4 |
Part Numbers – SM TRX Access Control (2, 3 or 4 beams)
Model Number | Protected Height (mm) | Overall Height (mm) | Number of Beams |
SM TRX 2B | 510 | 500 | 2 |
SM TRX 3B | 810 | 400 | 3 |
SM TRX 4B | 910 | 300 | 4 |