Description
JANUS MT TRX
Muting functions and passive retro-reflector element.
MT TRX features four horizontal arms (two for the emitter and two for the receiver) with built-in pre-wired and pre-aligned photoelectric Muting sensors that do not require any adjustment.
Both the light grid and sensor arms are composed of an active, emitter/receiver element and of a passive, retro-reflector element, requiring no wiring
Specifications
Degree of protection: IP65
Muting sensors: Reflex optoelectronics with 2 parallel beams built-in – pre-aligned – pre-wired, with adjustable height and angle
Signaling: 7-segment display and LEDs for self-diagnosis and light curtain status
Compliance
Safety level Type 4
SIL 3 SILCL 3 Cat. 4 PL e
Technical Data
Model | Operating Range | Supply Voltage | Safety Outputs | Muting Logic | Electrical Connections | Protection Rating | Safety Rating |
---|---|---|---|---|---|---|---|
MT TRX | 0m to 3.5m | 24 VDC ± 20% | 2 fail-safe PNP – 500 mA at 24 VDC | Two-way with 2 sensors | Emitter M12 5-pole Receiver: M23 19-pole Muting sensors: M12 5-pole |
IP 65 | Type 4 SIL 3 – SILCL 3 PL e – Cat. 4 |
MT TRX G (Muting is suitable for transparent materials) | 0m to 2m | 24 VDC ± 20% | 2 fail-safe PNP – 500 mA at 24 VDC | Two-way with 2 sensors | Emitter M12 5-pole Receiver: M23 19-pole Muting sensors: M12 5-pole |
IP 65 | Type 4 SIL 3 – SILCL 3 PL e – Cat. 4 |
Accessories
- columns and floor support columns
- deflection mirrors for the realization of perimeter protection
- laser alignment device
- anti-vibration dampers
- adjustable brackets
Part Numbers
PROTECTED HEIGHT (MM) | BEAM SPACING (MM) | OVERALL HEIGHT (MM) | NUMBER OF BEAMS | ORDER/MODEL NUMBER |
---|---|---|---|---|
510 | 500 | 776 | 2 | MT 2B TRX |
810 | 400 | 1076 | 3 | MT 3B TRX |
460 | 500 | 776 | 2 | MT 2B TRX G |
810 | 400 | 1076 | 3 | MT 3B TRX G |
A = 776mm