Idem 131101: MMC-H 2NC Right 2M | Non-Contact Safety Switches
“Non-Contact Coded Magnetic Safety Switch for Secure Interlocking System.”
Request a quote
Attribute | Value |
---|---|
Approvals: | TUV, cULus |
Coding Level according to EN ISO 14119: | Low |
Technology: | Coded Magnetic, Hall effect |
Housing Material: | 316 Grade Stainless Steel |
Normally Closed Contacts: | Up to 3 N/C Safety (When the Guard is Closed) |
Normally Open Contacts: | Up to 1 N/O Auxiliary (When the Guard is Closed) |
Switching Distance: | Sao 8mm / Sar 20mm |
Response Time (OFF): | 60ms Maximum |
Tolerance to Misalignment: | 5mm in any Direction from 5mm Setting Gap |
Indication: | Green LED when Guard is Closed |
Connectivity: | 2m, 5m, 10m, M12 QC |
Length: | 41mm |
Width: | 26mm |
Height: | 13mm |
IP Rating: | IP67, IP69K |
Ambient Temperature: | -25 … +105 °C |
Storage Temperature: | -25 … +105 °C |
Power Consumption: | 25mA Max. |
Maximum Switched Current (Outputs): | 200mA (Minimum Internal Resistance 8.5ohms) |
Switching Frequency: | 1.0 Hz Maximum |
Approach Speed: | 200mm/m. to 1000mm/s. |
Cable: | PVC 6mm O.D. Conductors 0.25 sq.mm |
ISO 13849-1: | Up to PLe Category 4 (if both channels are used with a PLe control device) |
Pfhd: | 2.6 x 10-10 (1/h) |
Proof Test Interval (life): | 20 years |
Mttfd: | 866 years |
UL Info: | Type 1 Enclosures. Maximum temperature 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent. |
Product Number | Variant Description |
---|---|
131116 | MMC-H 2NC QC-M12 8way Left |
131120 | MMC-H 2NC 1NO QC-M12 8way Left |
131102 | MMC-H 2NC Right 5M |
131117 | MMC-H 2NC 1NO Left 2M |
131103 | MMC-H 2NC Right 10M |
131108 | MMC-H 2NC 1NO QC-M12 8way Right |
131115 | MMC-H 2NC Left 10M |
131119 | MMC-H 2NC 1NO Left 10M |
131113 | MMC-H 2NC Left 2M |
131118 | MMC-H 2NC 1NO Left 5M |
131104 | MMC-H 2NC QC-M12 8way Right |
131105 | MMC-H 2NC 1NO Right 2M |
131106 | MMC-H 2NC 1NO Right 5M |
131107 | MMC-H 2NC 1NO Right 10M |
131114 | MMC-H 2NC Left 5M |