Idem 113200: CPR Spare Actuator | Non-Contact Safety Switches
“Reliable magnetic safety switch for non-contact interlocking systems.”
Request a quote
Attribute | Value |
---|---|
Coding Level according to EN ISO 14119: | Low |
Technology: | Magnetic |
Housing Material: | Red, Polyester |
Normally Closed Contacts: | Up to 2 N/C Safety (When the Guard is Closed) |
Tolerance to Misalignment: | 5mm in any Direction from 5mm Setting Gap |
Connectivity: | 2m, 5m, 10m, M12 QC |
Length: | 85mm |
Width: | 20.6mm |
Height: | 17mm |
IP Rating: | IP67 |
Ambient Temperature: | -25 … +80 °C |
Storage Temperature: | -25 … +80 °C |
Switching Frequency: | 1.0Hz max. |
Approach Speed: | 200mm/m. to 1000mm/s. |
Cable: | PVC 6.0mm OD Conductors 0.25 sq.mm |
ISO 13849-1: | Up to PLe Category 4(if both channels are used with a PLe control device) |
Certificates: | TUV, cULus |
Contact Release Time: | <2ms |
Switching Current, Minimum: | 10V. Dc 1mA |
Switching Voltage, Maximum (2NC): | 240V.ac / 24V.dc 1.0A. max. (Fuse externally 0.8A. (F). |
Auxiliary Circuits (NO): | 24V.ac/dc 0.2A. max. |
B10d: | 3,300,000 cycles at 100mA load |
Usage: | 8 cycles/hour 24 hours/365 days per yearMTTFd is 470 years |
Switching Voltage, Maximum (1NC): | 240V.ac / 24V.dc 2.0A. max. (Fuse externally 1.6A. (F). |
Normally Open Contacts: | Up to 1 N/O Auxiliary (When the Guard is Closed) |