Euchner 161562E | MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode
MGBS-P-L1H-AR-U-L-SH-161562 is a safety switch designed to ensure operational safety in various applications.
Request a quote
Attribute | Value |
---|---|
Rated insulation voltage Ui: | 50 V |
Approach speed: | max. 20 m/min |
Connection Type: | 1 plug connector M23, 19-pin, RC18 |
Actuating force: | 10 N |
Installation Orientation: | Door hinge DIN left |
Mechanical Life: | 1 x 10? |
Degree of protection: | IP65(screwed tight plug connector/mating component) |
Item designation: | MGBS-P-L1H-AR-U-L-SH-161562 |
Gross weight: | 3,8kg |
ECLASS: | 27-27-24-05 Safety-related transponder switch with guardlocking |
Turn-on time: | max. 400 ms |
EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3: | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device: | max. 5 ms |
Degree of contamination (external, according to EN 60947-1): | 3 |
Output Type: | 2 semiconductor outputs, p-switching, short circuit-proof |
Off-state Current Ir: | max. 0.25 mA |
Test Pulse Duration: | max. 1.0 ms(Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test Pulse Interval: | min. 140 ms |
Ready Delay: | 8 s |
Switching frequency: | max. 0.5 Hz |
Shock And Vibration Resistance: | Acc. to EN IEC 60947-5-3 |
Additional feature: | incl. lens set, ID no. 120344 |
Overtravel: | 5 mm |
Product version number: | V1.0.0 |
Rated impulse withstand voltage Uimp: | 0.5 kV |
Locking force FZh: | 3000 N(Fzh = Fmax/1.3, depending on the actuator used) |
Guard locking principle: | Closed-circuit current principle |
Operating voltage: | UB V |
Operating current: | 1 … 50 mA |
Extraction Force: | 20 N |
Retention Force: | 20 N |
Locking force Fmax: | 3900 N |
Power consumption: | 6 W |
Solenoid Duty Cycle: | 100 % |
The following applies to the approval according to UL: | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Product Number | Variant Description |
---|---|
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1HE-AR-U-R-SH-160520 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1HE-AR-U-L-SH-160521 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L2H-AR-U-R-SH-160522 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L2H-AR-U-L-SH-160523 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1HE-AR-U-R-SH-160879 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1HE-AR-U-L-SH-161557 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1H-AR-U-R-SH-161561 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1H-AR-U-R-SH-161563 : Safety Switch Unicode |
MGBS-P-L1H-AR-U-L-SH-161562 : Safety Switch Unicode | MGBS-P-L1H-AR-U-L-SH-161564 : Safety Switch Unicode |