Euchner 121289E | MSC-CB-AC-FI8FO2-121289 : Small Safe Control System Base Unit
$1,467.78
Explore the Euchner 121289E | MSC-CB-AC-FI8FO2-121289 : Small Safe Control System Base Unit. Now sold at Venus Automation. Request a quote now!
Request a quote
| Attribute | Value |
|---|---|
| Product Code: | 121289E |
| Dimensions: | 108 x 22.5 x 114.5(Including screw terminals) |
| Connection Type: | USB type B – Mini |
| Storage temperature: | -20 … 85 °C |
| Degree of protection: | IP20 |
| Ambient temperature: | -10 … 55 °C |
| Order Number: | 121289 |
| Item designation: | MSC-CB-AC-FI8FO2-121289 |
| Gross weight: | 0,141kg |
| Customs tariff number: | 85371091 |
| ECLASS: | 27-24-22-07 SPS-Grundgerät |
| Connection Cross Section: | 0.5 … 2.5 mm²(Screw terminal) |
| Atmospheric humidity: | 10 … 95 % rH |
| Mission time: | 20 y(according to ISO 13849-12006/IEC 620612005) |
| Category: | 4(according to ISO 13849-12006/IEC 620612005) |
| Performance Level: | PL e(according to ISO 13849-12006/IEC 620612005) |
| PFHD: | 6.85E-9 1/h(according to IEC 615082010) |
| Degree of contamination according to EN 60664-1: | 2 |
| Mounting type: | Mounting rail TH 35 (EN IEC 60715) |
| Test Pulse Interval: | 20 ms |
| Cable length: | max. 3 m |
| Overvoltage category according to IEC EN 60664-1: | II |
| Power Dissipation: | max. 3 W |
| Time delay: | 0.0106 … 0.0546 s + filter time(Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions or calculated values in the Euchner Safety Designer software)) |
| SIL CL: | 3 |