Euchner 119470E | CES-I-AR-U-C04-U05-119470 : Safety Switch
$741.11
Explore the Euchner 119470E | CES-I-AR-U-C04-U05-119470 : Safety Switch. Now sold at Venus Automation. Request a quote now!
Request a quote
| Attribute | Value |
|---|---|
| Product Code: | 119470E |
| Connection Type: | Connecting cable PUR, length 5 m |
| Installation Orientation: | any |
| Storage temperature: | -30 … 70 °C |
| Degree of protection: | IP67 |
| Order Number: | 119470 |
| Item designation: | CES-I-AR-U-C04-U05-119470 |
| Gross weight: | 0,226kg |
| Customs tariff number: | 85365019000 |
| ECLASS: | 27-27-24-03 Safety-related transponder switch |
| Additional feature: | Rubber support included |
| Rated insulation voltage Ui: | 30 V |
| Rated impulse voltage Uimp: | 0.5 kV |
| EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
| Safety Class: | III |
| Current consumption: | max. 35 mA(without taking into account the load currents on the monitoring output and the safety outputs) |
| Degree of contamination (external, according to EN 60947-1): | 3 |
| Switching frequency: | max. 1 Hz |
| Shock And Vibration Resistance: | Acc. to EN IEC 60947-5-3 |
| Output Type: | Semiconductor outputs, p-switching, short circuit-proof |
| Off-state Current Ir: | max. 0.25 mA |
| Test Pulse Duration: | max. 1.0 ms(Applies to a load with C<= 30nF and R<= 20kOhm) |
| Mounting type: | Surface mounting on metal |
| Discrepancy time: | max. 10 ms |
| Risk time according to EN 60947-5-3: | max. 260 ms |
| Risk time according to EN 60947-5-3, extension for each additional device: | max. 5 ms |
| Test Pulse Interval: | min. 140 ms |
| Ready Delay: | 10 s |
| Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures |
| Dynamic bending radius: | 10 x cable diameter |
| Cable ambient temperature (dynamic): | -25 … 65 °C |
| Cable ambient temperature (static): | -30 … 65 °C |
| Static bending radius: | 5 x cable diameter |
| Rated Conditional Short-circuit Current: | 100 A |