Euchner 105752E | CES-AR-CL2-CH-SG-105752 : Safety Switch

The CES-AR-CL2-CH-SG-105752 is a reliable safety switch designed to ensure operational safety in various applications.

Request a quote

    Attribute Value
    Rated insulation voltage Ui: 75 V
    Rated impulse voltage Uimp: 1.5 kV
    Connection Type: M8 plug connector, 8-pin
    Installation Orientation: any
    Degree of protection: IP67/IP69K
    Ambient temperature: -25 … +65 °C
    Item designation: CES-AR-CL2-CH-SG-105752
    Gross weight: 0,1kg
    ECLASS: 27-27-24-03 Safety-related transponder switch
    Mounting type: non-flush on metal
    EMC protection requirements: Acc. to EN IEC 60947-5-3
    Risk time according to EN 60947-5-3: max. 260 ms
    Risk time according to EN 60947-5-3, extension for each additional device: max. 5 ms
    Safety Class: III
    Current consumption: max. 50 mA(without taking into account the load currents on the monitoring output and the safety outputs)
    Degree of contamination (external, according to EN 60947-1): 3
    Output Type: Semiconductor outputs, p-switching, short circuit-proof
    Rated Conditional Short-circuit Current: 100 A
    Discrepancy time: max. 10 ms
    Off-state Current Ir: max. 0.25 mA
    Test Pulse Duration: max. 1 ms(Applies to a load with C<= 30 nF and R<= 20 kohm)
    Test Pulse Interval: min. 140 ms
    Ready Delay: 10 s
    Switching frequency: max. 1 Hz
    Shock And Vibration Resistance: Acc. to EN IEC 60947-5-3
    Notices For UL Approval: Operation only with UL Class 2 power supply or equivalent measures
    Switch-on Distance: 15 mm
    Secured switching distance sao: min. 10 mm
    Switching hysteresis: 1 … 2 mm
    Product Number Variant Description
    CES-AR-CL2-CH-SG-105752 : Safety Switch (No others)