Euchner 098582E | CES-AR-C01-EH-SA : Ces In Series – Fixcode

The CES-AR-C01-EH-SA is a versatile Ces In Series device that allows for secure and efficient connection in various applications.

Request a quote

    Attribute Value
    Rated insulation voltage Ui: 75 V(Tested up to 75 V by employers’ liability insurance association)
    Rated impulse voltage Uimp: 1.5 kV
    Connection Type: M12 plug connector, 8-pin
    Installation Orientation: any
    Degree of protection: IP65/IP67/IP69/IP69K
    Ambient temperature: -25 … +70 °C
    Item designation: CES-AR-C01-EH-SA
    Gross weight: 0,22kg
    ECLASS: 27-27-24-03 Safety-related transponder switch
    Power Supply: Inductive via read head
    EMC protection requirements: Acc. to EN IEC 60947-5-3
    Risk time according to EN 60947-5-3: max. 260 ms
    Risk time according to EN 60947-5-3, extension for each additional device: max. 5 ms
    Safety Class: III
    Degree of contamination (external, according to EN 60947-1): 3
    Output Type: Semiconductor outputs, p-switching, short circuit-proof
    Rated Conditional Short-circuit Current: max. 100 A
    Discrepancy time: max. 10 ms
    Off-state Current Ir: max. 0.25 mA
    Test Pulse Duration: max. 1 ms
    Ready Delay: 10 s
    Switching frequency: max. 1 Hz
    Mounting distance: min. 40 mm
    Shock And Vibration Resistance: Acc. to EN IEC 60947-5-3
    Notices For UL Approval: Operation only with UL Class 2 power supply or equivalent measures
    Switch-on Distance: 22 mm(on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm)
    Secured Switch-off Distance Sar: max. 58 mm
    Secured switching distance sao: min. 18 mm
    Switching hysteresis: 1 … 2 mm
    Included Accessories: 2x safety screws M5x10
    Product Number Variant Description
    CES-AR-C01-EH-SA : Ces In Series – Fixcode (No others)