Euchner 097945E | CES-A-C5H-01-EX : Evaluation Unit
$1,616.67
Explore the Euchner 097945E | CES-A-C5H-01-EX : Evaluation Unit. Now sold at Venus Automation. Request a quote now!
Request a quote
Attribute | Value |
---|---|
Product Code: | 097945E |
Operating voltage DC: | 21 … 24 … 27 V DC regulated, residual ripple<5% |
Dimensions: | Acc. to EN 60947-5-2 |
Connection Type: | M12 plug connector, 8-pin; shield can be connected |
Installation Orientation: | any |
Storage temperature: | -25 … 70 °C |
Degree of protection: | IP65/IP67 |
Order Number: | 097945 |
Item designation: | CES-A-C5H-01-EX |
Gross weight: | 0,545kg |
Customs tariff number: | 85365019000 |
ECLASS: | 27-27-24-03 Safety-related transponder switch |
Secured Switch-off Distance Sar: | max. 40 mm |
Rated insulation voltage Ui: | 50 V |
Rated impulse voltage Uimp: | 0.5 kV |
EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
Current consumption: | 80 mA |
Degree of contamination (external, according to EN 60947-1): | 3 |
Switching frequency: | max. 1 Hz |
Output Type: | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled(To ensure safety, both safety outputs (LA and LB) must be evaluated.) |
Global Trade Item Number (GTIN): | 4047048006355 |
Switching hysteresis: | 2 … 3 mm(for surface mounting of the actuator) |
Ready Delay: | max. 3 s(After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set to LOW level during the ready delay.) |
Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures |
Rated Conditional Short-circuit Current: | 100 A |
Dwell time: | min. 0.5 s(The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |