Euchner 097525E | CES-A-W5H-01 : Evaluation Unit
The CES-A-W5H-01 Evaluation Unit is designed for testing and evaluating various electronic components and systems.
Request a quote
Attribute | Value |
---|---|
Rated insulation voltage Ui: | 75 V(Tested by the employers liability insurance association up to 75 V.) |
Rated impulse voltage Uimp: | 1.5 kV |
Connection Type: | M12 plug connector, 8-pin; shield can be connected |
Installation Orientation: | any |
Degree of protection: | IP65/IP67 |
Item designation: | CES-A-W5H-01 |
Gross weight: | 0,349kg |
ECLASS: | 27-27-24-03 Safety-related transponder switch |
Operating voltage DC: | 18 … 24 … 27 V DC regulated, residual ripple<5% |
EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
Current consumption: | 80 mA |
Degree of contamination (external, according to EN 60947-1): | 3 |
Output Type: | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled(To ensure safety, both safety outputs (LA and LB) must be evaluated.) |
Rated Conditional Short-circuit Current: | max. 100 A |
Ready Delay: | max. 3 s(After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set to LOW level during the ready delay.) |
Switching frequency: | max. 1 Hz |
Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures |
Secured Switch-off Distance Sar: | max. 58 mm |
Switching hysteresis: | 1 … 2 mm(for non-flush mounting; assembly on aluminum) |
Dwell time: | min. 0.5 s(The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Dimensions: | according to EN 60947-5-2 (LxWxH) 131x40x40 |
Product Number | Variant Description |
---|---|
CES-A-W5H-01 : Evaluation Unit | (No others) |