“YASKAWA ELECTRIC; SGMPH-01AAE4CD; SERVO MOTOR, SIGMA – II, CUBE TYPE, 0.1 KW, 0.1 kW” has been added to your cart.
“ASEA BROWN BOVERI; ACH550-PCR-031A-4; AC DRIVE” has been added to your cart.
“ASEA BROWN BOVERI; BALDOR RELIANCE; ID15H575-EO; AC INVERTER” has been added to your cart.
“Idem 141005B-FZ: GLHL 4NC 2NO M20 E-Stop & LED 110V/120v” has been added to your cart.
“ASEA BROWN BOVERI; 3HAC5466-1; CABELING LOWER” has been added to your cart.
“Idem 200019HF-SS: KP-Ex 2NC 3M 4 core SS head HF actuator” has been added to your cart.
“CONTINENTAL HYDRAULICS; Variable Speed Drive05M-1A-AB-60L-B; SOLENOID OPERATED DIRECTIONAL CONTROL VALVE” has been added to your cart.
“ASEA BROWN BOVERI; ACS800-04-0016-5+J400; AC DRIVE” has been added to your cart.
“SEW EURODRIVE; MC07A008-2B1-4-00; AC INVERTER DRIVE” has been added to your cart.

Euchner 087413E | ESM-BA303 : Safety Relay
$794.44
Explore the Euchner 087413E | ESM-BA303 : Safety Relay. Now sold at Venus Automation. Request a quote now!
Request a quote
| Attribute | Value |
|---|---|
| Product Code: | 087413E |
| Degree of protection: | IP20 |
| Ambient temperature: | -15 … 40 °C(If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between the devices must be observed.) |
| Order Number: | 087413 |
| Item designation: | ESM-BA303 |
| Gross weight: | 0,298kg |
| Customs tariff number: | 85364110 |
| ECLASS: | 27-37-18-19 Device for monitoring of safety-related circuits |
| Rated insulation voltage Ui: | 250 V |
| Degree of contamination (external, according to EN 60947-1): | 2 |
| Switching current: | min.5 mAat 24V |
| Mission time: | 20 y(This value is dependent on the number of switching cycles and the switching current.) |
| Category: | 4(This value is dependent on the number of switching cycles and the switching current.) |
| Performance Level: | PL e(This value is dependent on the number of switching cycles and the switching current.) |
| PFHD: | 1.2 x 10-8(This value is dependent on the number of switching cycles and the switching current.) |
| Overvoltage category according to IEC EN 60664-1: | 3 |
| Number of safety contacts: | 3 |
| Contact material: | AgSnO2 |
| Mounting method: | Mounting rail 35mm according to DIN EN 60715 TH35 |
| Connection: | Connection terminals |
| Number of auxiliary contacts: | 1 |
| Connection Cross-section: | 0,14 … 2,5 mm²(Connection terminal (size)) |
| LED Indicator: | 2 status displays (green) for relays K1 and K2 |
| Breaking capacity according to UL: | 8A 250V AC / 3A 24V DC per contact |
| Cumulative current: | max.15 AFor all contacts(If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between the devices must be observed.) |
| In compliance with: | EN ISO 13849-1 2015; EN 62061 2005 + AC 2010 + A1 2013 + A2 2015; EN 50581 2012 (RoHS) |
| Rated Supply Frequency: | 50 … 60 Hz |
| Breaking capacity (VA): | max.500 VA |