Euchner 087412E | ESM-BA302 : Safety Relay
$794.44
Explore the Euchner 087412E | ESM-BA302 : Safety Relay. Now sold at Venus Automation. Request a quote now!
Request a quote
| Attribute | Value |
|---|---|
| Product Code: | 087412E |
| Degree of protection: | IP20 |
| Ambient temperature: | -15 … 40 °C(If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20°C is 9A; at T=30°C is 3A; at T=40°C is 1A. If these currents are exceeded, a spacing of 5mm between the devices must be observed.) |
| Order Number: | 087412 |
| Item designation: | ESM-BA302 |
| Gross weight: | 0,295kg |
| Customs tariff number: | 85364110 |
| ECLASS: | 27-37-18-19 Device for monitoring of safety-related circuits |
| Rated insulation voltage Ui: | 250 V |
| Degree of contamination (external, according to EN 60947-1): | 2 |
| Switching current: | min.5 mAat 24V |
| Mission time: | 20 y(This value is dependent on the number of switching cycles and the switching current.) |
| Category: | 4(This value is dependent on the number of switching cycles and the switching current.) |
| Performance Level: | PL e(This value is dependent on the number of switching cycles and the switching current.) |
| PFHD: | 1.2 x 10-8(This value is dependent on the number of switching cycles and the switching current.) |
| Overvoltage category according to IEC EN 60664-1: | 3 |
| Number of safety contacts: | 1 |
| Contact material: | AgSnO2 |
| Mounting method: | Mounting rail 35mm according to DIN EN 60715 TH35 |
| Connection: | Connection terminals |
| Connection Cross-section: | 0,14 … 2,5 mm²(Connection terminal (size)) |
| LED Indicator: | 2 status displays (green) for relays K1 and K2 |
| Breaking capacity according to UL: | 2A 250V AC / 2A 24V DC per contact |
| Cumulative current: | max.15 AFor all contacts(If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current at the ambient temperature of T=20 °C is 9 A; at T=30 °C is 3 A; at T=40 °C is 1 A. If these currents are exceeded, a spacing of 5mm between the devices must be observed.) |
| In compliance with: | EN ISO 13849-1 2015; EN 62061 2005 + AC 2010 + A1 2013 + A2 2015; EN 50581 2012 (RoHS) |
| Rated Supply Frequency: | 50 … 60 Hz |
| Breaking capacity (VA): | max.500 VA |