Description
The Pizzato CS MF Series offers a versatile range of pre-configured safety controllers designed for various industrial safety applications. Each model in this series provides different safety functions to meet specific requirements, including monitoring multiple guards in AND logic, emergency stop functionality, and options for either automatic or manual monitored start. Some models are equipped with bypass selectors, general enabling signals, and independent output configurations for enhanced control. Additionally, select units support advanced configurations, such as delayed outputs and selectable On/Off delays, making them suitable for setups with guard locking or specific operating principles
Downloads
Product Code | Functions Executed | Safety Outputs | Signalling Outputs |
---|---|---|---|
CS MF201M0-P1 | Monitoring of 2 guards in AND and 1 emergency stop with automatic start or manual monitored start. | 3 NO | 4 PNP |
CS MF202M0-P2 | Monitoring of 4 guards in AND, 1 bypass selector, 1 emergency stop, automatic start or manual monitored start, general enabling signal. | 4 PNP | 4 PNP |
CS MF202M0-P3 | Monitoring of 6 guards in AND (2NC contacts), 1 emergency stop, automatic start or manual monitored start. | 4 PNP | 4 PNP |
CS MF202M0-P4 | Monitoring of 6 guards in AND (1NO+1NC contacts), 1 emergency stop, automatic start or manual monitored start. | 4 PNP | 4 PNP |
CS MF202M0-P5 | Monitoring of 4 guards with independent outputs, 1 bypass selector, 1 emergency stop, automatic start or manual monitored start, general enabling signal. | 4 PNP | 4 PNP |
CS MF202M0-P6 | Monitoring of 2 guards, 1 bypass selector, 1 emergency stop, automatic start or manual monitored start, general enabling signal. Three instantaneous outputs and one delayed output with selector switch with 4 times. Selectable On/Off delay. | 4 PNP | 4 PNP |
CS MF202M0-P7 | Monitoring of 4 guards (AND linked) with switches with guard locking, operating principle “D”, 1 emergency stop, monitored start. Two instantaneous outputs and two delayed outputs with selector switch with 4 times. | 4 PNP | 4 PNP |
CS MF202M0-P8 | Monitoring of 4 guards in AND with switches with guard locking, operating principle “E”, 1 emergency stop, monitored start. Two instantaneous outputs and two delayed outputs with selector switch with 4 times. | 4 PNP | 4 PNP |
CS MF204M0-P10 | Monitoring of 4 guards in AND (OSSD outputs) and 1 emergency stop with automatic start or manual monitored start. | 3 NO | 4 PNP |