Euchner 105139E | CES-AZ-UES-01B : Evaluation Unit
The CES-AZ-UES-01B is an evaluation unit designed for assessing performance and functionality in various applications.
Request a quote
Attribute | Value |
---|---|
Rated insulation voltage Ui: | 250 V |
Rated impulse voltage Uimp: | 4 kV |
Connection Type: | plug-in connection terminals, coded(Terminals not included) |
Degree of protection: | IP20 |
Item designation: | CES-AZ-UES-01B |
Gross weight: | 0,229kg |
ECLASS: | 27-27-24-03 Safety-related transponder switch |
Mounting type: | TH 35 mounting rail (EN IEC 60715) |
EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1): | 2 |
Output Type: | Relay contacts, floating |
Output voltage: | 0.8 x UB … UB V DC |
Rated Conditional Short-circuit Current: | 100 A |
Ready Delay: | 10 … 12 s(After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.) |
Switching frequency: | max. 0.25 Hz(In case of monitoring with feedback loop, the actuators must remain outside the actuating range, e.g. with a door open, until the feedback loop is closed) |
Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures. |
Secured Switch-off Distance Sar: | max. 21 mm |
Number of safety contacts: | 2 Relay with internally monitored contacts |
Number of read heads: | 1 read head can be connected |
Dwell time: | min. 3 s(The dwell time is the time that the actuator must be outside the actuating range.) |
Current Via Feedback Loop: | 5 … 8 … 10 mA |
permissible resistance in feedback loop: | max. 600 ? |
Product Number | Variant Description |
---|---|
CES-AZ-UES-01B : Evaluation Unit | CES-AZ-UES-02B : Evaluation Unit |
CES-AZ-UES-01B : Evaluation Unit | CES-AZ-UES-04B : Evaluation Unit |