
CES-AP-CR2-CH-SF-100775 : Safety Switch
Non-contact safety switch CES-AP-CR2-… , with latching connection
Request a quote
Attribute | Value |
---|---|
Mounting type: | non-flush on metal |
Degree of protection: | IP67/IP69K |
Ambient temperature: | -30 … +65 °C |
Ordernumber: | 100775 |
Item designation: | CES-AP-CR2-CH-SF-100775 |
Gross weight: | 0,08kg |
Customs tariff number: | 85365019000 |
ECLASS: | 27-27-24-03 Safety-related transponder switch |
Rated insulation voltage Ui: | 75 V |
Rated impulse withstand voltage Uimp: | 1.5 kV |
EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3: | max. 260 ms |
Safety Class: | III |
Current consumption: | max. 30 mA(without taking into account the load currents on the monitoring output and the safety outputs) |
Degree of contamination (external, according to EN 60947-1): | 3 |
Output Type: | Semiconductor outputs, p-switching, short circuit-proof |
Rated Conditional Short-circuit Current: | 100 A |
Discrepancy time: | max. 10 ms |
Off-state Current Ir: | max. 0.25 mA |
Test Pulse Duration: | max. 0.3 ms(Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test Pulse Interval: | min. 100 ms |
Connection Type: | Plug connector with latching connection, Ø8, 6-pin |
Ready Delay: | 0.5 s |
Installation Orientation: | any |
Switching frequency: | max. 1 Hz |
Shock And Vibration Resistance: | Acc. to EN IEC 60947-5-3 |
The following applies to the approval according to UL: | Operation only with UL Class 2 power supply or equivalent measures |
Switch-on Distance: | 15 mm |
Secured switching distance sao: | min. 10 mm |
Switching hysteresis: | 1 … 2 mm |