CES-AP-CL2-CH-SF-104509 : Safety Switch

Non-contact safety switch CES-AP-CL2-… , with latching connection

Request a quote

    Attribute Value
    Mounting type: non-flush on metal
    Degree of protection: IP67/IP69K
    Ambient temperature: -30 … +65 °C
    Ordernumber: 104509
    Item designation: CES-AP-CL2-CH-SF-104509
    Gross weight: 0,094kg
    Customs tariff number: 85365019000
    ECLASS: 27-27-24-03 Safety-related transponder switch
    Rated insulation voltage Ui: 75 V
    Rated impulse withstand voltage Uimp: 1.5 kV
    EMC protection requirements: Acc. to EN IEC 60947-5-3
    Risk time according to EN 60947-5-3: max. 260 ms
    Safety Class: III
    Current consumption: max. 30 mA(without taking into account the load currents on the monitoring output and the safety outputs)
    Degree of contamination (external, according to EN 60947-1): 3
    Output Type: Semiconductor outputs, p-switching, short circuit-proof
    Rated Conditional Short-circuit Current: 100 A
    Discrepancy time: max. 10 ms
    Off-state Current Ir: max. 0.25 mA
    Test Pulse Duration: max. 0.3 ms(Applies to a load with C<= 30 nF and R<= 20 kohm)
    Test Pulse Interval: min. 100 ms
    Connection Type: Plug connector with latching connection, Ø8, 6-pin
    Ready Delay: 0.5 s
    Installation Orientation: any
    Switching frequency: max. 1 Hz
    Shock And Vibration Resistance: Acc. to EN IEC 60947-5-3
    The following applies to the approval according to UL: Operation only with UL Class 2 power supply or equivalent measures
    Switch-on Distance: 15 mm
    Secured switching distance sao: min. 10 mm
    Switching hysteresis: 1 … 2 mm