CES-A-UBA-01B : Evaluation Unit
Evaluation unit CES-A-UBA… (for 1 read head)
Request a quote
Attribute | Value |
---|---|
Mounting type: | TH 35 mounting rail (EN IEC 60715) |
Degree of protection: | IP20 |
Ordernumber: | 96961 |
Item designation: | CES-A-UBA-01B |
Gross weight: | 0,244kg |
Customs tariff number: | 85364110 |
ECLASS: | 27-27-24-03 Safety-related transponder switch |
Rated insulation voltage Ui: | 63 V |
Rated impulse withstand voltage Uimp: | 1.5 kV |
EMC protection requirements: | Acc. to EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1): | 2 |
Output Type: | Relay contacts, floating |
Output voltage: | 0.8 x UB … UB V DC |
Rated Conditional Short-circuit Current: | 100 A |
Connection Type: | plug-in screw terminals, coded |
Ready Delay: | max. 3 s(After the operating voltage is switched on, the relay outputs are switched off and the door monitoring contact is set to LOW level during the ready delay.) |
Switching frequency: | max. 1 Hz(If the current load is>100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.) |
The following applies to the approval according to UL: | Operation only with UL Class 2 power supply or equivalent measure. |
Secured Switch-off Distance Sar: | max. 47 mm |
Output Current: | max. 20 mA |
Number of read heads: | 1 read head can be connected |