EUCHNER: CES Evaluation Units

The evaluation unit can be configured so that a start button (monitoring of the falling edge) and a feedback loop can be
connected to monitor external relays and contactors.

Request a quote

    Model Product Code Evaluation Unit Type Description Safety Rated
    CES-AZ-AES 104770 (1 read head)
    104775 (2 read heads)
    104780 (4 read heads)
    Unicode:
    Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in.
    Category 4/PL e according to EN ISO 13849-1
    2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
    Yes
    CES-AZ-UES 105139 (1 read head)
    105140 (2 read heads)
    105141 (4 read heads)
    Multicode:
    Every suitable actuator is detected by the evaluation unit.
    Category 4/PL e according to EN ISO 13849-1
    2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
    Yes
    CES-AZ-ALS 113090 (4 read heads) Unicode:
    Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in.
    Category 4/PL e according to EN ISO 13849-1
    2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
    Yes