CES-A-UEA-02B : Evaluation Unit

Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads)

Request a quote

    Attribute Value
    Mounting type: TH 35 mounting rail (EN IEC 60715)
    Degree of protection: IP20
    Ordernumber: 97077
    Item designation: CES-A-UEA-02B
    Gross weight: 0,321kg
    Customs tariff number: 85364110
    ECLASS: 27-27-24-03 Safety-related transponder switch
    Rated insulation voltage Ui: 250 V
    Rated impulse withstand voltage Uimp: 4 kV
    EMC protection requirements: Acc. to EN 60947-5-3
    Degree of contamination (external, according to EN 60947-1): 2
    Output Type: Relay contacts, floating
    Output voltage: 0.8 x UB … UB V DC
    Rated Conditional Short-circuit Current: 100 A
    Connection Type: Screw terminals
    Ready Delay: 10 … 12 s(After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
    Switching frequency: max. 0.25 Hz(In case of monitoring with feedback loop, the actuators must remain outside the actuating range, e.g. with a door open, until the feedback loop is closed.)
    The following applies to the approval according to UL: Operation only with UL Class 2 power supply or equivalent measures.
    Secured Switch-off Distance Sar: max. 47 mm
    Number of read heads: max. 2 read heads can be connected