Idem 470001: MLZ 24Vdc RFID Locking Switch OSSD IP69K 5m | Non-Contact Safety Switches
“Hygienic RFID safety switch with guard locking & OSSD features (MLZ).”
Request a quote
Attribute | Value |
---|---|
Approvals: | TUV (pending), cULus |
Technology: | RFID, Power to Unlock |
Housing Material: | 316 Grade Stainless Steel |
Power Consumption: | R+ (50mA Max.) / S+ (500mA Max.) (Solenoid) |
Mttfd: | 771a |
UL Info: | Type 1 enclosure. Use Class 2 power supply or equivalent.Maximum temperature 40°C. Maximum output 24V.dc 100mA. |
Performance Level: | e |
Category: | Cat 4 |
Diagnostic Coverage DC: | High |
Safety Integrity Level: | SIL 3 |
PFH (1/h): | 1.0 E-09 (Corresponds to 1% of SIL3) |
Proof Test Interval T1: | 20a |
Enclosure Protection: | IP67, IP69K (QC version is IP67 at the connector) |
Operating Temperature: | -25 … +55 °C |
Vibration: | IEC68-2-6, 10-55Hz+1Hz Excursion 0.35mm, 1 octave/min |
Supply Voltage: | 24Vdc (+/- 10%) SELV/PELV or Class 2 |
Outputs Rated Voltage: | 24 Vdc |
Response Time Guard Open: | 60ms max. |
Response Time Inputs Off: | 20ms max. |
Actuator entry minimum radius: | 175mm |
Outputs Max. Current: | 0.1 A |
Outputs Min. Current: | 1 mA |
Inputs Rated Voltage: | 24 Vdc |
Inputs Rated Current: | 2 mA |
Dielectric Withstand: | 250V.ac |
Insulation Resistance: | 100 Mohms |
Classification and Coding Level according to EN ISO 14119: | Type 4, High |
Mechanical Life Expectancy (b10d): | 2.5 x 10 6 cycles at 100mA load |
Holding Force (ISO14119): | F1Max 4000N Fzh 3077N |
Sao / Sar (RFID): | 10mm / 20mm |
PFD (Av.): | 8.7 E-05 (Corresponds to 9% of SIL3) |
Outputs Type: | OSSD, PNP |
Adjustable Spring Ball Catch: | Adjustable 30 100N. (Light latch) |
Coding level (ISO14119): | Type 4 High |
Assured Locking distance: | 6mm |
Product Number | Variant Description |
---|---|
470002 | MLZ 24Vdc RFID Locking Switch OSSD IP69K 10m |
470003 | MLZ 24Vdc RFID Locking Switch OSSD IP69K QC-M12 |