Euchner 109052E | CES-AR-CR2-CH-L20-109052 : Safety Switch
$1,167.78
Explore the Euchner 109052E | CES-AR-CR2-CH-L20-109052 : Safety Switch. Now sold at Venus Automation. Request a quote now!
Request a quote
| Attribute | Value | 
|---|---|
| Product Code: | 109052E | 
| Connection Type: | Connecting cable PUR, length 20 m | 
| Installation Orientation: | any | 
| Storage temperature: | -30 … 70 °C | 
| Degree of protection: | IP67/IP69K | 
| Order Number: | 109052 | 
| Item designation: | CES-AR-CR2-CH-L20-109052 | 
| Gross weight: | 0,8kg | 
| Customs tariff number: | 85365019000 | 
| ECLASS: | 27-27-24-03 Safety-related transponder switch | 
| Rated insulation voltage Ui: | 75 V | 
| Rated impulse voltage Uimp: | 1.5 kV | 
| EMC protection requirements: | Acc. to EN IEC 60947-5-3 | 
| Safety Class: | III | 
| Current consumption: | max. 50 mA(without taking into account the load currents on the monitoring output and the safety outputs) | 
| Degree of contamination (external, according to EN 60947-1): | 3 | 
| Switching frequency: | max. 1 Hz | 
| Shock And Vibration Resistance: | Acc. to EN IEC 60947-5-3 | 
| Output Type: | Semiconductor outputs, p-switching, short circuit-proof | 
| Switching hysteresis: | 1 … 2 mm | 
| Off-state Current Ir: | max. 0.25 mA | 
| Test Pulse Duration: | max. 1 ms(Applies to a load with C<= 30nF and R<= 20kOhm) | 
| Mounting type: | Surface mounting on metal | 
| Discrepancy time: | max. 10 ms | 
| Risk time according to EN 60947-5-3: | max. 260 ms | 
| Risk time according to EN 60947-5-3, extension for each additional device: | max. 5 ms | 
| Test Pulse Interval: | min. 140 ms | 
| Ready Delay: | 10 s | 
| Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures | 
| Dynamic bending radius: | 10 x cable diameter | 
| Cable ambient temperature (dynamic): | -25 … 65 °C | 
| Cable ambient temperature (static): | -30 … 65 °C | 
| Static bending radius: | 5 x cable diameter | 
| Rated Conditional Short-circuit Current: | 100 A | 
| Switch-on Distance: | 19 mm | 
| Secured switching distance sao: | min. 14 mm | 
 
	 
								 
								