CES Evaluation Units
Description
The evaluation unit can be configured so that a start button (monitoring of the falling edge) and a feedback loop can be
connected to monitor external relays and contactors.
Specifications
Downloads
The evaluation unit can be configured so that a start button (monitoring of the falling edge) and a feedback loop can be
connected to monitor external relays and contactors.
Model | Product Code | Evaluation Unit Type | Description | Safety Rated |
---|---|---|---|---|
CES-AZ-AES | 104770 (1 read head) 104775 (2 read heads) 104780 (4 read heads) | Unicode: Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in. | Category 4/PL e according to EN ISO 13849-1 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) | Yes |
CES-AZ-UES | 105139 (1 read head) 105140 (2 read heads) 105141 (4 read heads) | Multicode: Every suitable actuator is detected by the evaluation unit. | Category 4/PL e according to EN ISO 13849-1 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) | Yes |
CES-AZ-ALS | 113090 (4 read heads) | Unicode: Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in. | Category 4/PL e according to EN ISO 13849-1 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) | Yes |