title

GI 9014

Motor Soft Starter

Description/Specifications

  • 2-phase softstarter for asynchronous motors up to 110 kW (400V)
  • Integrated current control time
  • Integrated motor protector
  • Integrated bridging contactor
  • Volt free control input for softstart/stop
  • Connection for motor thermistor
  • With two monitoring outputs, one is programmable
  • DIN rail mounting with devices up to 30 kW
  • Communication interfaces for Profibus, DeviceNet, Modbus and pump controls (optional)
  • Start and stop via separate push buttons or control switch
  • Motor voltage range 3 AC 200…400V or 3 AC 200…575V

Specifications

  • Softstarter for asynchronous motors up to 110 kW (400 V)
  • Integrated current control
  • Integrated motor protection
  • Integrated bridging contactor
  • Voltfree control input for softstart and stop
  • Connection for motor thermistor
  • 1 Programmable monitoring output
  • Units up to 30 kW for DIN rail mounting
  • Communication module for Profibus, DeviceNet, Modbus and pump controls (as option)
  • Available for common or seperate start-stop buttons.

Dimensions

Power Unit: Width x Height x Depth

7.5/15/18.5/22/30 kW: 98 x 203 x 165 mm

37/45/55 kW: 145 x 215 x 193 mm

75/90/110 kW: 202 x 240 x 214 mm

Technical Specifications

Model Product Number Input Output Protection Degree
DOLD Motor Soft starter – MINISTART GI 9014 Start (terminal 01) –
NO contact:
150 kΩ at AC 300V
5.6 kΩ at DC 24 VStop (terminal 02) –
NC contact:
150 kΩ at AC 300V
5.6 kΩ at DC 24V
Main Contactor (terminals 13,14) –
NO contact:
2 A, AC 400 V, AC11
6 A, DC 30 V, resistiveProgrammable Relay (terminals 23,24) –
NO contact:
2 A, AC 400 V, AC11
6 A, DC 30 V, resistive
7.5 ~ 55 kW: IP 20 (IEC/EN 60 529)

75 ~ 110 kW: IP 00 (IEC/EN 60 529)