Wieland SNV 4063KL-A | 2NO safety relay with 1NO 0.15-150s off-delayed output
Base unit, single-channel or two-channel control, automatic/manual reset with reset switch monitoring, 2 immediately switching current paths, 1 enabling current path off-delayed, 24 VDC, screw-terminals pluggable
Request a quote
Part Number | Ordering Code | Outputs | Terminals | Supply Voltage |
SNV4063KL-A
|
R1.188.0620.0 | 2NO, 1NO Off-delay 0.15-3 seconds, 230VAC 6A | Screw Terminal | 24VDC |
R1.188.0640.0 | 2NO, 1NO Off-delay 1.5-30 seconds, 230VAC 6A | Screw Terminal | 24VDC | |
R1.188.4100.0 | 2NO, 1NO Off-delay 7.5-150 seconds, 230VAC 6A | Screw Terminal | 24VDC | |
SNV4063KL-C
|
R1.188.2010.0 | 2NO, 1NO Off-delay 0.15-3 seconds, 230VAC 6A | Push-in Terminal | 24VDC |
R1.188.3900.0 | 2NO, 1NO Off-delay 1.5-30 seconds, 230VAC 6A | Push-in Terminal | 24VDC |
[read more]
Introducing SNV 4063KL: Your Safety Automation Solution
Key Features:
1. Time Delay Functionality
The SNV 4063KL comes equipped with advanced time delay features. With adjustable time delays ranging from 0.15 to 3 seconds or 1.5 to 30 seconds, you have the flexibility to fine-tune the response time based on your specific requirements. This ensures that your safety measures are precisely tailored to your operations.
2. Ensuring Safety at Every Step
With the SNV 4063KL, you can be confident that safety is always prioritized. From the emergency stop function that immediately interrupts the current supplies for relays K1 to K4 to the electronic fuse protection that safeguards the device from damage, the SNV 4063KL goes the extra mile to protect your processes and personnel.
3. Two-Channel Control and Cross-Monitoring
The device supports two-channel control and cross-monitoring wiring of the sensor circuit. This capability enables the detection of additional errors, such as short-circuits or ground faults, providing an added layer of safety and ensuring the integrity of your control systems.
4. Reset Button Monitoring
The SNV 4063KL offers versatile reset button monitoring options. You can initiate the device with either the falling edge or rising edge of the reset signal. For manual start applications, connect the button to terminals S33/S34, and for automatic start scenarios, bridge terminals S33/S35. The system ensures seamless and secure operation in both cases.
5. Synchronous Time Monitoring
Safety gate applications require precise synchronous time monitoring. The SNV 4063KL provides reliable monitoring of the synchronous time of two connected safety switches. The system ensures that channel 1 closes before channel 2, reducing potential hazards and ensuring optimal safety during your operations.
[/read]
Attribute | Value |
---|---|
Safety rating: |
Up to SIL 3 Category 4 PL e |
Protection rating: |
IP 40 for housing, IP 20 for terminals |
EN ISO 13849-1
EN 62061
EN 80-20/50
EN 50156-1:2005 SNS 3
EN 61511