DOLD BH 9253 | Reversing contactor

The reversing contactor BH 9253 is used to reverse the direction of 3-phase asynchronuos motors by switching 2 phases. An electrical interlocking disables the control of both directions at the same time. The reversing contactor has a short on and off delay time. When reversing the phases a switchover delay is guaranteed. To protect the power semiconductors the unit incorporates temperature monitoring. When overtemperature is detected the power semiconductors swith off and an output relay as well as a red LED is activated. This state is stored. When the temperature is back to normal the semiconductors can be activated again by switching off and on the control voltage.

Request a quote

    Technical Specifications

    Model Product Number Switch Delay Switching Capacity Protection Degree
    DOLD Reversing Contactors BH 9253 On: Max. 30 msOff: Typically 25 ms

    Switch-over: 100 ms

    At AC 15:NO: 3 A / AC 230 V (IEC/EN 60 947-5-1)

    NC: 1 A / AC 230 V (IEC/EN 60 947-5-1)

    Housing: IP 40 (IEC/EN 60 529)

    Terminals: IP 20 (IEC/EN 60 529)

    • According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
    • Switching at zero-crossing
    • To reverse 3 phase asynchronous motors up to
      5.5 kW / 400 V (7.5 HP / 460 V)
    • Electrical interlocking of both directions
    • Temperature monitoring to protect the power semiconductors
    • Measured nominal current up to 20 A
    • LEDs for status indication
    • Galvanic separation between control circuit and power circuit

    Width x Height x Depth:

    112.5 x 67.5 x 45 mm

    Technical Data Sheet