Technical Data

ModelOperating Range
Supply VoltageSafety OutputsMuting LogicElectrical Connections
Protection RatingSafety Rating
MT TRX0m to 3.5m24 VDC ± 20% 2 fail-safe PNP – 500 mA at 24 VDCTwo-way with 2 sensors
Emitter M12 5-pole
Receiver: M23 19-pole
Muting sensors: M12 5-pole
IP 65
Type 4
SIL 3 – SILCL 3
PL e – Cat. 4
MT TRX G (Muting is suitable for transparent materials)0m to 2m24 VDC ± 20% 2 fail-safe PNP – 500 mA at 24 VDCTwo-way with 2 sensors
Emitter M12 5-pole
Receiver: M23 19-pole
Muting sensors: M12 5-pole
IP 65
Type 4
SIL 3 – SILCL 3
PL e – Cat. 4

Part Numbers

Protected Height (mm)Beam Spacing (mm)Overall Height (mm)Number of BeamsOrder/Model Number
5105007762MT 2B TRX
81040010763MT 3B TRX
4605007762MT 2B TRX G
81040010763MT 3B TRX G

A = Overall Height